SAE AMS3198 Sponge, Chloroprene (CR) Rubber, Medium Stiffness

作者:标准资料网 时间:2024-05-17 02:59:02   浏览:8561   来源:标准资料网
下载地址: 点击此处下载
Product Code:SAE AMS3198
Title:Sponge, Chloroprene (CR) Rubber, Medium Stiffness
Issuing Committee:Ams Ce Elastomers Committee
Scope:This specification covers a chloroprene (CR) rubber sponge in the form of sheet, strip, molded shapes, or other forms, as ordered. These products have been used typically for general applications requiring the use of open-cell, medium sponge rubber pads and seals operating from -40 to +80 degrees C (-40 to +176 degrees F), but usage is not limited to such applications.
下载地址: 点击此处下载
基本信息
标准名称:道路车辆装载物固定装置 安全性 第2部分:合成纤维栓紧带总成
英文名称:Load restraint assemblies on road vehicles—Safety—Part 2:Web lashing assembly made from synthetic fibres
中标分类: 公路、水路运输 >> 公路运输 >> 货运
ICS分类:
发布部门: 交通运输部
发布日期:2009-06-04
实施日期:2010-01-01
首发日期:2009-06-04
作废日期:
主管部门: 交通运输部
提出单位:中华人民共和国交通运输部
归口单位: 交通运输部
起草单位:中华人民共和国交通部公路司
起草人:杨建国、张学利、李彦英、张万铭、李廷树、陈卫东、董金松、刘至国
出版社:中国标准出版社
出版日期:2010-01-01
页数:20页
计划单号:20076405-T-348
适用范围

GB/T23914的本部分规定了合成纤维栓紧带总成(以下简称为栓紧带)的风险提示、要求、试验方法和检验规则、试验报告、标识、包装、运输和贮存等。
本部分规定的最大操作力为500N 的手动拉紧装置,适用于装载物的栓紧、捆绑及安全固定。
本部分不适用于吊装用合成纤维栓紧带。

前言

没有内容

目录

没有内容

引用标准

没有内容

所属分类: 公路 水路运输 公路运输 货运
【英文标准名称】:StandardPracticeforSelectionofBloodforInVitroEvaluationofBloodPumps
【原文标准名称】:评价实验室血泵用血液的选择的标准操作规程
【标准号】:ASTMF1830-1997(2005)
【标准状态】:现行
【国别】:
【发布日期】:1997
【实施或试行日期】:
【发布单位】:美国材料与试验协会(US-ASTM)
【起草单位】:F04.30
【标准类型】:(Practice)
【标准水平】:()
【中文主题词】:血液损伤;溶血指数;试验血的条件状况;供血源
【英文主题词】:bloodtrauma;conditionoftestblood;indexofhemolysis;sourceofblooddonor
【摘要】:Thetestresultsaresubstantiallyaffectedbydonorspeciesandage,themethodofharvesting,theperiodofstorage,thebiochemicalstateoftheblood,andthehemoglobinandhematocritlevelofblood.3,4Therefore,standardizationofproperbloodusageforinvitroevaluationofbloodpumpsisessential,andthisrecommendedpracticewillallowauniversalcomparisonoftestresults.Drawingseveralunitsofbloodfromhealthycattledoesnotaffectthemortheirhealth.Therefore,bovinebloodisstronglysuggestedforusageinexperimentalevaluationofblooddamage.Mixingtwodonorsourcesofbloodshouldbeavoidedinhemolysistestsbecausethemixturemayinduceaddedhemolysisorachangeinredcellresistanceagainsttrauma.1.1Thispracticecoversbloodthatwillbeusedforinvitroperformanceassessmentsofbloodpumps.Theseassessmentsincludethehemolyticpropertiesofthedevices.1.2Thispracticecoverstheutilizationofbloodfortheinvitroevaluationofthefollowingdevices:1.2.1Continuousflowrotarybloodpumps(rollerpumps,centrifugalpumps,axialflowpumps,andsoforth)(seePracticeF1841).1.2.2Pulsatilebloodpumps(pneumaticallydriven,electromechanicallydriven,andsoforth).1.3Thesourceofbloodutilizedforinvitroevaluationofbloodtrauma(thatis,hemolysiscausedbythebloodpumps,duetothepumpdesign,construction,andmaterialsused)substantiallyinfluencestheresultsoftheperformanceofthesedevices.Thus,astandardizedbloodsourceisrequired.
【中国标准分类号】:C34
【国际标准分类号】:11_100
【页数】:2P.;A4
【正文语种】: